EasyManua.ls Logo

Mitsubishi Electric EZMOTION MR-E Super MR-E-70A-QW003 - Installation Direction and Clearances

Mitsubishi Electric EZMOTION MR-E Super MR-E-70A-QW003
326 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 2
2. INSTALLATION
2.2 Installation direction and clearances
CAUTION
The equipment must be installed in the specified direction. Otherwise, a fault may
occur.
Leave specified clearances between the servo amplifier and control box inside
walls or other equipment.
(1) Installation of one servo amplifier
MODE
CN3
SET
CN1
CN2
CNP2
CNP1
L3L2L1 D C P W V U
CHARGE
MITSUBISHI
MR-
Control box Control box
10mm
or more
10mm
or more
40mm
or more
Servo
amplifier
40mm
or more
Wiring clearance
Top
Bottom
70mm
(2) Installation of two or more servo amplifiers
Leave a large clearance between the top of the servo amplifier and the internal surface of the control box,
and install a cooling fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
MODE
CN3
SET
CN1
CN2
CNP2
CNP1
L3L2L1 D C P W V U
CHARGE
MITSUBISHI
MR-
MODE
CN3
CN1
CN2
CNP2
CNP1
L3L2L1 D C P W V U
CHARGE
MITSUBISHI
MR-
SET
Control box
30mm
or more
30mm
or more
10mm
or more
40mm
or more
100mm
or more
Top
Bottom
www.DataSheet4U.com

Table of Contents

Related product manuals