3 - 8
3. SIGNALS AND WIRING
3.1.2 Internal speed control mode
LZR
LA
LAR
LB
LBR
LG
RD
10m max.
1
9
12
RA1
RA2
8
4
3
5
6
7
EMG
SON
ST1
ST2
LSP
LSN
VIN 1
ALM
ZSP
CN3
VIN
CN1
4
3
SD
6
MO1
LG
MO2
10k
10k
A
A
CN3
20
19
21
17
16
18
LZ
SD
14
15
11
10 SA
RA3
RA4
13 SG
Plate
Personal
computer
CN1
(Note 7)
(Note 5)
Trouble
Zero speed
(Note 2)
Control common
Encoder Z-phase pulse
(differential line driver)
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
(Note 6)
Communication cable
(Note 6)
Monitor output
Max. 1mA
Reading in
both directions
(Note 1)
Servo amplifier
(Note 7)
Speed reached
Ready
Plate
(Note 3, 4) Emergency stop
Servo-on
Forward rotation start
Reverse rotation start
(Note 4) Forward rotation stroke end
Reverse rotation stroke end
External
power
supply
24VDC
(Note 7)
(Note 7)
(Note 9)
Encoder Z-phase pulse
(open collector)
OP
2m max.
(Note 8)
MR Configurator
(Servo configuration software)
Note 1. To prevent an electric shock, always connect the protective earth (PE) terminal (terminal marked ) of the servo amplifier to the
protective earth (PE) of the control box.
2. Connect the diode in the correct direction. If it is connected reversely, the servo amplifier will be faulty and will not output signals,
disabling the emergency stop and other protective circuits.
3. The emergency stop switch (normally closed contact) must be installed.
4. When starting operation, always connect the emergency stop (EMG) and forward rotation stroke end (LSN), reverse rotation stroke
end (LSP) with VIN. (Normally closed contacts)
5. Trouble (ALM) is connected with VIN in normal alarm-free condition.
6. When connecting the personal computer together with monitor outputs 1, 2, use the branch cable (MR-E3CBL15-P). (Refer to
section 13.1.3)
7. The pins with the same signal name are connected in the servo amplifier.
8. Use MRZJW3-SETUP154E of 154C.
9. Externally supply 24VDC
10 , 200mA power for the interface. 200mA is a value applicable when all I/O signals are used.
Reducing the number of I/O points decreases the current capacity. Refer to the current necessary for the interface described in
section 3.6.2. Connect the external 24VDC power supply if the output signals are not used.
www.DataSheet4U.com