15 - 64
15. MR-E- AG-QW003 SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
15.6.2 Alarms and warning list
POINT
Configure up a circuit which will detect the trouble (ALM) signal and turn off
the servo-on (SON) signal at occurrence of an alarm.
When a fault occurs during operation, the corresponding alarm or warning is displayed. If any alarm or warning
has occurred, refer to section 10.2.2 or 10.2.3 and take the appropriate action. When an alarm occurs, the
current circuit between ALM and VIN opens.
Set "
1" in parameter No.49 to output the alarm code in ON/OFF status across the corresponding pin
and VIN. Warnings (AL.E0 to AL.E9) have no alarm codes. Any alarm code is output at occurrence of the
corresponding alarm. In the normal status, the signals available before alarm code setting (CN1-12: ZSP, CN1-
11: RD, CN1-10: SA) are output.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
in the alarm
deactivation column.
(Note 2) Alarm code Alarm deactivation
Display
CN1-10
pin
CN1-11
pin
CN1-12
pin
Name
Power
OFF
ON
Press
"SET" on
current
alarm
screen.
Alarm reset
(RES)
signal
AL.10 0 1 0 Undervoltage
AL.12 0 0 0 Memory error 1
AL.13 0 0 0 Clock error
AL.15 0 0 0 Memory error 2
AL.16 1 0 1 Encoder error 1
AL.17 0 0 0 Board error
AL.19 0 0 0 Memory error 3
AL.1A 1 0 1 Motor combination error
AL.20 1 1 0 Encoder error 2
AL.24 0 0 1 Main circuit error
AL.30 0 1 0 Regenerative error (Note 1) (Note 1) (Note 1)
AL.31 0 1 1 Overspeed
AL.32 0 0 1 Overcurrent
AL.33 0 1 0 Overvoltage
AL.37 0 0 0 Parameter error
AL.45 1 1 0 Main circuit device overheat
AL.46 1 1 0 Servo motor overheat
AL.50 1 1 0 Overload 1 (Note 1) (Note 1) (Note 1)
AL.51 1 1 0 Overload 2 (Note 1) (Note 1) (Note 1)
AL.8A 0 0 0 Serial communication time-out error
AL.8E 0 0 0 Serial communication error
Alarms
88888 0 0 0 Watchdog
AL.E0 Excessive regenerative warning
AL.E1 Overload warning
AL.E6 Servo emergency stop warning
Warnings
AL.E9
Undervoltage warning
Removing the cause of occurrence
deactivates the alarm
automatically.
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. 0: off
1: on
www.DataSheet4U.com