Appendix 5 List of Special Register Areas
SD1376 Module error cause of
iQ Sensor Solution
data backup/
restoration
Module error cause of
data backup/
restoration
This register stores the error cause that is detected in the module
during the iQ Sensor Solution data backup/restoration. When
errors are detected in multiple devices, the error detected first is
stored. (For details on the error cause stored, refer to the manual
for the CPU module used or the target device.)
This register is cleared to 0 when the right to use is acquired or
the backup/restoration is requested.
S (Status
change/Error)
Rn
*3
SD1377 Target device error
cause of iQ Sensor
Solution data backup/
restoration
Target device error
cause of data backup/
restoration
This register stores the error cause that is detected in the target
device during the iQ Sensor Solution data backup/restoration.
When errors are detected in multiple devices, the error detected
first is stored. (For details on the error cause stored, refer to the
manual for the target device.)
This register is cleared to 0 when the right to use is acquired or
the backup/restoration is requested.
S (Status
change/Error)
Rn
*3
SD1378 Module information/
execution unit
information of iQ
Sensor Solution data
backup/restoration
error
Module information/
execution unit
information of an
error
At an occurrence of the iQ Sensor Solution data backup/
restoration error, this register stores the information of the
module where the error has been occurred and the execution
unit information. When errors are detected in multiple devices,
the information of a device where the error detected first is
stored.
Lower 8 bits (target module)
1H: AnyWireASLINK
2H: CC-Link
3H: Ethernet
4H: CC-Link IE Field Network
Upper 8 bits (execution unit)
<AnyWireASLINK>
1H: In module units
2H: In ID units
<CC-Link and CC-Link IE Field Network>
1H: In module units
2H: In station units
3H: In station sub ID units
<Ethernet>
1H: In module units
2H: In IP address units
This register is cleared to 0 when the right to use is acquired or
the backup/restoration is requested.
S (Status
change/Error)
Rn
*3
SD1379 Folder number
information of iQ
Sensor Solution data
backup/restoration
error
Folder number
information of an
error
At an occurrence of the iQ Sensor Solution data backup/
restoration error, this register stores the folder number (0 to 99)
of the backup/restoration target. If the folder number cannot be
specified or a backup error is detected before creating a backup
folder (I/O number_station number), FFFFH is stored.
This register is cleared to 0 when the right to use is acquired or
the backup/restoration is requested.
S (Status
change/Error)
Rn
*3
SD1380 Details on iQ Sensor
Solution data backup/
restoration error
(module)
Information of the
module where an
error has occurred
This register stores the information of a module where an error of
the iQ Sensor Solution data backup/restoration has been
occurred. When errors are detected in multiple modules, the
information of a module where the error detected first is stored.
I/O number.
*1
: Module
3FFH: Built-in Ethernet
*2
This register is cleared to 0 when the right to use is acquired or
the backup/restoration is requested.
S (Status
change/Error)
Rn
*3
No. Name Data stored Details Set by