992
APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
File Transfer Error Log
The following window displays the error history of the data logging file transfer function. Up to 20 errors are displayed. When
the number of errors exceeds 20, records are deleted in order from the oldest one. The error history is retained after the
power is off and on or the reset operation is performed.
Window
Displayed items
*1 When the data logging file transfer is stopped or there is no file to be transferred, "" is displayed.
*2 Even when the FTP server is specified with the server name in the server setting, the IP address is displayed. However, when the server
is not connected, "" is displayed.
Item Description
Status The file transfer status is displayed.
•Error
Date The date when the data logging file transfer function error occurred is displayed.
Data Logging Setting No. The data logging setting No. where the data logging file transfer function error has occurred is displayed.
File Name The data logging file name where the data logging file transfer function error has occurred is displayed.
*1
File Transfer Server The IP address of the transfer destination server where the data logging file transfer function error has occurred is
displayed.
*2
Error Code The data logging file transfer function error that has occurred is displayed.
[...] button This button is displayed when an error has occurred. Clicking this button displays the error details window.
[Update] button Clicking this button obtains the error history in the CPU module again and displays it.
[Clear Log] button Clicking this button clears the error history in the CPU module.