36 ERROR CODES
36.4 List of Error Codes
573
36
2481H Multiple CPU
error
In a multiple CPU system, any CPU
module other than CPU No.1 was
disconnected from the base unit
during operation. Or, any CPU
module other than CPU No.1 was
reset.
Stop Check the mounting status and
reset status of the CPU modules
other than CPU No.1.
System
configuration
information
Always
24C0H System bus
error
An error was detected on the system
bus.
Stop CPU module
Take measures to reduce noise.
Reset the CPU module and run it
again. If the same error code is
displayed again, the possible
cause is a hardware failure of the
CPU module, base unit, extension
cable, or module (I/O module or
intelligent function module)
connected. Please consult your
local Mitsubishi representative.
Redundant function module
The possible cause is malfunction
due to noise. Take measures to
reduce noise by checking the
distance of wires and cables, and
the grounding status of each
device.
Execute a module communication
test. If the same error code is
displayed again, the possible
cause is a hardware failure of the
redundant function module.
Please consult your local
Mitsubishi representative.
System
configuration
information
At module
access
24C1H
24C2H System bus
error
The I/O module or intelligent function
module is not mounted properly or
was removed during operation.
An error was detected on the system
bus.
Stop CPU module
Check the detailed information
(system configuration information)
of the error by executing module
diagnostics using the engineering
tool and check the module
corresponding to the displayed
slot number.
Check the connection status of the
extension cable.
Take measures to reduce noise.
Reset the CPU module and run it
again. If the same error code is
displayed again, the possible
cause is a hardware failure of the
CPU module, base unit, extension
cable, or module (I/O module or
intelligent function module)
connected. Please consult your
local Mitsubishi representative.
Redundant function module
The possible cause is malfunction
due to noise. Take measures to
reduce noise by checking the
distance of wires and cables, and
the grounding status of each
device.
Execute a module communication
test. If the same error code is
displayed again, the possible
cause is a hardware failure of the
redundant function module.
Please consult your local
Mitsubishi representative.
System
configuration
information
Always
Error
code
Error name Error details and cause Stop/
continue
Action Detailed
information
Diagnostic
timing