1 FUNCTIONS
1.17 Redundant System Function
237
1
8. Set the redundant settings in the following items.
[Navigation window] [Parameter] [Module Information] [RJ71EN71] [Port 1 Module Parameter (Ethernet)]
[Application Settings] [Redundant System Settings]
9. Set whether to issue a system switching request for the user connection.
[Navigation window] [Parameter] [Module Information] [RJ71EN71] [Port 1 Module Parameter (Ethernet)]
[Application Settings] [Redundant System Settings] [System Switching Request Issue at Communication Error]
[User Connection]
10. In the "System A/B Setting" window, set the redundant function module of own system to system A, and either reset the
CPU modules of both systems or power off and on both systems.
[Online] [Redundant PLC Operation] [System A/B Setting]