15
RELEVANT MANUALS
e-Manual refers to the Mitsubishi Electric FA electronic book manuals that can be browsed using a dedicated
tool.
e-Manual has the following features:
Required information can be cross-searched in multiple manuals.
Other manuals can be accessed from the links in the manual.
The hardware specifications of each part can be found from the product figures.
Pages that users often browse can be bookmarked.
Sample programs can be copied to the engineering tool.
TERMS
Unless otherwise specified, this manual uses the following terms.
Manual name [manual number] Description Available form
MELSEC iQ-R Channel Isolated Analog-Digital Converter Module
User's Manual (Application)
[SH-081487ENG] (this manual)
Functions, parameter settings, troubleshooting, I/O
signals, and buffer memory of the A/D converter
module
Print book
e-Manual
PDF
MELSEC iQ-R Channel Isolated Analog-Digital Converter Module
User's Manual (Startup)
[SH-081485ENG]
Performance specifications, procedures before
operation, wiring, programming, and offset/gain setting
of the A/D converter module
Print book
e-Manual
PDF
MELSEC iQ-R Programming Manual (Module Dedicated
Instructions)
[SH-081976ENG]
Dedicated instructions for the intelligent function
modules
e-Manual
PDF
Term Description
A/D converter module The abbreviation for the MELSEC iQ-R series channel isolated analog-digital converter module
Buffer memory A memory in an intelligent module for storing data (such as setting values and monitored values) to be transferred
to the CPU module
Engineering tool Another term for GX Works3
Factory default setting A generic term for analog input ranges of 0 to 10V, 0 to 5V, 1 to 5V, -10 to 10V, 0 to 20mA, 4 to 20mA, 1 to 5V
(extended mode), and 4 to 20mA (extended mode).
In the window on the engineering tool, 4 to 20mA (extended mode) and 1 to 5V (extended mode) are displayed as
the following:
4 to 20mA (Extension)
1 to 5V (Extension)
Global label A label that is valid for all the program data when multiple program data are created in the project. There are two
types of global label: a module specific label (module label), which is generated automatically by GX Works3, and
an optional label, which can be created for any specified device.
GX Works3 The product name of the software package for the MELSEC programmable controllers
Module Label A label that represents one of memory areas (I/O signals and buffer memory areas) specific to each module in a
given character string. For the module used, GX Works3 automatically generates this label, which can be used as
a global label.
Normal mode A mode used for normal A/D conversion.
In the engineering tool, the item name of the mode is displayed as "Normal mode (A/D conversion process)".
Offset/gain setting mode A mode used for performing the offset/gain setting
Q compatible mode A mode in which the module operates with the buffer memory map converted to the equivalent one of the MELSEC
Q series
R mode A mode in which the module operates with the buffer memory map that has been newly laid out in the MELSEC iQ-
R series
Remote head module The abbreviation for the RJ72GF15-T2 CC-Link IE Field Network remote head module
SIL2 mode A mode certified according to the safety requirements of IEC61508: 2010 SIL2 and IEC61511: 2015 SIL2
Standard mode A mode for using the A/D converter module in a normal system
User range An analog input range where any value can be set. This range can be set in the offset/gain setting.
Watchdog timer error An error that occurs if the internal processing of the A/D converter module fails. The module monitors its own
internal processing by using the watchdog timer.

Table of Contents