APPX
Appendix 3 Buffer Memory Areas
189
A
CH1 Logging cycle setting value
Set a cycle for storing the logging data.
For details on the logging function, refer to the following.
Page 61 Logging Function
■Buffer memory address
The following shows the buffer memory address of this area.
•CH Logging cycle setting value
•CH Logging cycle setting value (in Q compatible mode)
■Setting range
The setting range varies depending on the setting in 'CH1 Logging cycle unit setting' (Un\G538).
• If a value out of the range is set, a logging cycle setting value range error (error code: 1D1H) occurs. Logging cannot be
performed.
• If the set logging cycle is below the update cycle of data to be logged, a logging cycle setting disable error (error code:
1D2H) occurs. Logging cannot be performed.
■Enabling the setting
Turn on and off 'Operating condition setting request' (Y9).
■Default value
The default value is 160 for all channels.
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16
537 737 937 1137 1337 1537 1737 1937 2137 2337 2537 2737 2937 3137 3337 3537
CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16
1032 1033 1034 1035 1036 1037 1038 1039
CH1 Logging cycle unit setting (Un\G538) Setting range
ms (1) 10 to 32767
s (2) 1 to 3600