4 OPERATION CONTROL PROGRAMS
4.19 Other Instructions
When the waiting time setting is indirectly specified with a word device, the value imported first is used as
the device value for exercising control. The set time cannot be changed if the device value is changed
during a wait state.
The TIME instruction is equivalent to a conditional expression, and therefore may be set on only the last line
of a transition (G) program.
When the transition program (Gn) of the same number having the TIME instruction setting is used in
multiple Motion SFC programs, avoid running them at the same time. (If they are run simultaneously, the
waiting time in the program run first will be illegal.)
Another transition program (Gn) can executed a time of instruction by multiple Motion SFC program
simultaneously. (Multi active step up to 1024 (for operating system software version "08" or earlier, up to
256).)
While time by TIME instruction waits, the wait time can not be stopped.