Loading...
3 - 6 3 - 6
MELSEC-Q
3 SPECIFICATIONS
Device
No.
Signal name Details
Initial
value
*1
X10 CH1
X11 CH2
X12 CH3
X13 CH4
X14 CH5
X15 CH6
X16 CH7
X17 CH8
Accumulating
counter
comparison
flag
OFF: Accumulating
count value
Comparison
output setting
value
ON : Accumulating
count value
Comparison
output setting
value
This signal turns ON if the "accumulating count value"
reaches or exceeds the "comparison output setting value".
The "accumulating count value" is stored into the buffer
memory for each channel. Set the "comparison output
setting value" to the buffer memory for each channel.
(Refer to Section 3.4.2 for details.)
This signal remains ON until the comparison signal reset
request (Y10 to Y17) turns ON.
Once turned OFF, this signal does not turn ON until the
accumulating count value reaches the comparison output
setting value again after it has been reset.
Accumulating count value
OFF
ON
ON
Executed by QD60P8-G
OFF
Count cycle
setting value
Comparison output
setting value
A
ccumulating counter
comparison flag
(X10 to X17)
Comparison signal
reset request
(Y10 to Y17)
Executed by sequence program
OFF
*1: Initial value set at power-on or when the programmable controller CPU is reset.