9 Local time calculation
9.1 Basic setting control according to source of synchronization
P3
A
Time zone is taken over according to the source
of synchronization
P4
2 10,
A
Synchronization signal type
P6
0
Neither MOBALine time zone nor time zone
server are used
P7
A
Display time and date according to source of
synchronization incl. daylight saving time
This setting is suitable for digital clocks synchronized by a DCF receiver or controlled
by a master clock as slave clock in a time distribution system. The internal time zone
table isn’t used.
9.2 Calculation using MOBALine time zones
This setting is suitable for digital clocks controlled by a master clock as a MOBALine
slave clock in a time distribution system with possibility to display different MOBALine
time zones.
9.3 Calculation using time zone server MOBATIME
This setting is suitable for NTP and PoE digital clocks controlled by MOBATIME NTP
servers which support the time zone server functionality.
P3
A
Time zone is taken over according to the source of
synchronization. The UTC time calculation is based
on the MOBALine information.
P4
4
MOBALine
P6
1 - 20
Selection of the MOBALine time zone
P7
A
Display time and date according to chosen
MOBALine time zone, incl. daylight saving time
P3
A
NTP protocol uses UTC time zone
P4
A
automatic
P6
1 - 15
Selection of the time zone server time zone
P7
A
Display time and date according to chosen time
zone server time zone, incl. daylight saving time