6-6 Packet Reference Manual
To use the Expanded C1Gen2 data, you need to modify the RFID Field’s batch data.
Syntax field#,"EPC_data~028" |
C,"User_Mem~028" |
C,"~028" |
C,"Acs_Pwd~028" |
C,"Kill_Pwd~028" |
C,"Lock_Code" |
field# Identifies the RFID Data Field number for the following data.
Range: 1 to 999. 1 is the default.
"EPC_data~028" EPC data. Enclose in quotation marks. To create EPC data, follow
the guidelines in the EPC Global Generation 1 Tag Data Standards
Specification.
The printer can program up to 496-bits of data (124 ASCII Hex
characters). The data must end with the ASCII field separator
(decimal 028).
EPC data can be incremented by one. See “Incrementing EPC Data”
for more information.
Note: Do not enter more characters than the available EPC data. For example,
if the tag has 96-bits EPC data available, do not enter more than 96-bits of
data for this field.
C,"User_Mem~028" User Memory. Enclose in quotation marks. The amount of
programmable user memory varies with the tag types. The printer
programs up to 512-bits of data (128 ASCII Hex characters). The data
must be ASCII Hex characters and end with the ASCII field separator
(decimal 028).
C,"~028" Identifies information to be appended. Reserved for future use. Only
include the field separator (decimal 028) in this field.
C,"Acs_Pwd~028" Access Password. This must be 8 ASCII Hex characters. No
password is assigned if this field is left blank. The data must end with
the ASCII field separator (decimal 028).
C,"Kill_Pwd~028" Kill Password. This must be 8 ASCII Hex characters. No password is
assigned if this field is left blank. The data must end with the ASCII
field separator (decimal 028).
C,"Lock_Code" Five-digit locking method for each field in this order:
EPC Data, User Memory, TID (Reserved for future use), Access
password, and Kill password. Use 0 for the reserved field.
Locking options:
0 No Lock (unsecure)
1 Permalock (permanently unsecure)
2 Password lock (secure)
3 Permalock & password lock (permanently locked)
Note: Use only one locking method per field.
The printer is not capable of unlocking a field. Depending on the locking
method used for each field, the EPC data may be programmable by
sending the access password with the batch data. See “Sample RFID
Data Fields” in Appendix A for more information.
Do not use the ASCII file separator character (1C) in RFID batch data.