EasyManua.ls Logo

Monarch 9906 - Using Option 6 (Upload Field Data)

Monarch 9906
214 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-6 Packet Reference Manual
Using Option 6 (Upload Field Data)
You can upload data from any field using Option 6. When uploading multiple fields of data, the
data is comma separated.
Data is uploaded to the last port that received host data (serial, parallel, USB, or Ethernet) at the
end of the batch or label, depending on the other options used as follows:
When using a batch quantity of one without Option 60, data is uploaded at the end of the
batch.
When using a batch quantity greater than one with Option 60, data is uploaded after each
label.
Note: To upload data on a field that did not change, apply Option 60 to that field.
Syntax R,6,device |
R1. R Option Header.
R2. 6 Option 6.
R3. device Last port that received host data. Use H (host).
Example T,2,10,V,250,50,0,1,1,1,B,C,0,0,0 |
R,6,H |
Uploads the text field’s data to a file.
Example B,3,12,F,50,50,1,2,60,7,L,0 |
R,6,H |
R,60,I,0 |
Uploads the UPCA bar code field’s data to a file and uploads data for each label in the batch.
Example T,150,V,230,130,0,1,1,1,B,L,0,0 |
R,5,R |
R,6,H |
Reads the RFID data from the RFID chip embedded in the supply. Uploads the data to the last-
used port.
Example {F,1,A,R,E,600,400,"RDCI" |
X,5,24,0 |
T,6,20,V,415,270,0,50,15,15,B,L,0,2 |
R,4,5,1,16,1,0 |
R,6,H | }
Copies data from field 5 (RFID Data Field) to field 6 (Text field). Uploads the data to the last-
used port.