Configuring the Printer 2-7
Note: The Standard, Reduced, Bold, OCRA and HR fonts only support the
Internal Symbol Set (0). The CG Triumvirate™ typefaces only support the
ANSI (1) and DOS Code Page 437 (2) and 850 (3) Symbol Sets. The
scalable font (font#50) does not support Code Page 1256 Arabic (10).
Code pages 13-16 and 4-12 are for downloaded TrueType fonts or the
scalable font. Code pages 19-26 require the extended features printer and
a downloaded International TrueType font. TrueType fonts are designed to
be regionally specific; therefore, all code pages may not be supported in a
given font. See Appendix C, “Symbol Sets/ Code Pages” for more
information.
Example {I,A,0,0,1,1,0 | }
Powers up the printer in the online mode, displays prompts in English, prints a separator after
each batch, prints zeros with slashes through them, and uses the internal symbol set.
Defining the Supply Setup Packet
Use the supply setup packet (B) to select supply type, ribbon, feed mode, supply position, and
cut position.
Syntax {I,B,supply_type,ribbon,feed_mode,supply_posn,cut_posn,
skip_index | }
B1. B Supply Setup Packet
B2. supply_type Supply Type. 1 is the default. Options:
0 Black mark supply
1 Die Cut/edge aperture supply
2 Continuous (non-indexed) supply
Note: You must use continuous supply in continuous mode. For continuous
(non-indexed) supplies, the minimum feed length is 0.32 inches.
B3. ribbon Ribbon. 1 is the default. Options:
0 Ribbon not installed
1 Ribbon installed
2 High Energy Ribbon (use a print speed of 2.5 IPS; serial bar
codes cannot be printed using this ribbon). Settings for ribbon
and supply type must match the supplies loaded in the printer;
otherwise, an error occurs. To clear the error, turn off the printer
and change the configuration packet.
Turn on the printer and resend the packet.
B4. feed_mode Feed Mode. 0 is the default. Options:
0 Continuous operation
1 On-demand mode
2 Liner take-up (optional)
Note: For ease of tearing, use 3-inch long by 1-inch wide supplies that are less
than 5 mils thick. For peel mode, the minimum supply length is 1.50