Defining Fields 3-7
Defining Bar Code Fields
Each bar code field requires a separate definition.
Syntax B,field#,# of char,fix/var,row,column,font,density,height,
text,alignment,field rot,type,sep_height,segment |
B1. B Bar Code Field.
B2. field# Unique number from 1 to 999 to identify this field. 1 is the default.
B3. # of char Maximum number of characters. If the bar code uses a check digit,
allow an extra character for the check digit. The actual maximum
number of characters is limited by the size of the label and bar code
density. Range: 0 to 2710. 30 is the default.
Code 39 (w/ or w/o CD) or MOD43
0 – 2710 numeric; 0 – 2335 alphanumeric
GS1 DataBar Bar Code Type (B13)
13 - no check digit input
2 - GS1 DataBar 14 Truncated
13 - no check digit input
3 - GS1 DataBar 14 Stacked
13 - no check digit input
4 - GS1 DataBar 14 Stacked Omni
directional
13 - no check digit input
13 - no check digit input
11 - no check digit input
10 - no check digit input
12 - no check digit input
11 - UCC/EAN128 and CC A/B
If not enough characters are entered, the bar
code pads to the left with zeros. If too many
characters are entered, unpredictable results may
occur.
If FNC1 (function 1) is supported, use the pound sign (#) in the batch data to invoke it.
Refer to the GS1 General Specification for more information.