EasyManua.ls Logo

Monarch 9906 - Defining Bar Code Fields

Monarch 9906
214 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Defining Fields 3-7
Defining Bar Code Fields
Each bar code field requires a separate definition.
Syntax B,field#,# of char,fix/var,row,column,font,density,height,
text,alignment,field rot,type,sep_height,segment |
B1. B Bar Code Field.
B2. field# Unique number from 1 to 999 to identify this field. 1 is the default.
B3. # of char Maximum number of characters. If the bar code uses a check digit,
allow an extra character for the check digit. The actual maximum
number of characters is limited by the size of the label and bar code
density. Range: 0 to 2710. 30 is the default.
Bar Code
Number of Characters
Aztec
0 - 2710
Codabar (NW7)
0 2710
Code 16K
0 2710
Code 39 (w/ or w/o CD) or MOD43
0 2710
Code 93
0 2710
Code 128
0 2710
Data Matrix
0 2710 numeric; 0 2335 alphanumeric
EAN8
8
EAN8+2
10
EAN8+5
13
EAN13
13
EAN13+2
15
EAN13+5
18
EAN13+Price CD
13
GS1 DataBar Bar Code Type (B13)
1 - GS1 DataBar 14
13 - no check digit input
2 - GS1 DataBar 14 Truncated
13 - no check digit input
3 - GS1 DataBar 14 Stacked
13 - no check digit input
4 - GS1 DataBar 14 Stacked Omni
directional
13 - no check digit input
5 - GS1 DataBar Limited
13 - no check digit input
6 - GS1 DataBar Expanded
*
7 - UPCA
11 - no check digit input
8 - UPCE
10 - no check digit input
9 - EAN13
12 - no check digit input
10 - EAN8
7 - no check digit input
11 - UCC/EAN128 and CC A/B
If not enough characters are entered, the bar
code pads to the left with zeros. If too many
characters are entered, unpredictable results may
occur.
12 - UCC/EAN128 and CC C
If FNC1 (function 1) is supported, use the pound sign (#) in the batch data to invoke it.
Refer to the GS1 General Specification for more information.

Table of Contents

Other manuals for Monarch 9906

Related product manuals