8-6 Packet Reference Manual
Error Description
Code
216 Option definition must be S (set) or T (template).
217 Input device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).
218 Pad direction must be L (from left) or R (from right).
219 Pad character is outside the range 0 to 255.
220 Check digit selection must be G to generate check digit.
221 Primary or secondary price format is outside the range 1 to 16.
222 Data type restriction is outside the range of 1 to 6.
223 Option is not valid for the field.
224 Bar code intercharacter gap must be 0 to 99 dots. (This is also known as the additional
character gap when using Option 50, Defining Bar Code Densities.)
226 Rule (option) Record Line xx. The upload device must be H (host) for Option 6.
Online Configuration Errors
Error Description
Code
251 Power up mode must be 0 (online) or 1 (offline).
252 Language selection must be 0 (English), 1 (French), 2 (German), 3 (Spanish-ES), 4
(Japanese), 5 (Portuguese), 6 (Italian), 7 (Swedish), 8 (Spanish2-MX), 9 (Danish), 10
(Dutch), 11 (Finnish), 12 (Norwegian), 13 (Polish), 14 (Turkish), or 15 (Simplified
Chinese).
253 Batch separator code in a system setup packet must be 0 (off) or 1 (on).
254 Slash zero selection must be 0 (standard zero) or 1 (slashed zero).
255 Supply type must be 0 (black mark), 1 (die cut), 2 (continuous), or 3 (aperture).
256 Ribbon selection must be 0 (direct), 1 (transfer), or 2 (high energy).
257 Feed mode must be 0 (continuous), 1 (on-demand), or 2 (liner take-up).
258 Supply position must be -300 to 300 dots.
259 Contrast adjustment must be -699 to 699 dots.
260 Print adjustment (position) must be -450 to 450 dots.
261 Margin adjustment (position) must be -99 to 99 dots.
262 Speed adjustment must be 0 (default), 25 (2.5 ips), 40 (4.0 ips), or 60 (6.0 ips).
263 Primary monetary symbol must be 0 (None), 1 (Dollar), 2 (Pound), 3 (Yen), 4 (Deutsche
Mark), 5 (Franc), 6 (Peseta), 7 (Lira), 8 (Krona), 9 (Markka), 10 (Schilling), 11 (Rupee),
12 (Ruble), 13 (Won), 14 (Baht), 15 (Yuan), or 16 (Euro).
264 Secondary symbol selection must be 0 (none) or 1 (print secondary sign).
265 Monetary decimal places must be 0 to 3.
266 Character string length in the control characters packet must be 5 (MPCL control
characters) or 7 (ENQ/IMD command character).
267 Baud rate selection must be 0 (1200), 1 (2400), 2 (4800), 3 (9600), 4 (19200), 5 (38400),
6 (57600), or 7 (115200). Resend the communication settings packet.