Diagnostics and Errors 8-7
Error Description
Code
268 Word length selection must be 0 (7 bits), or 1 (8 bits). Resend the communication
settings packet.
269 Stop bits selection must be 0 (1 bit), or 1 (2 bits). Resend the communication settings
packet.
270 Parity selection must be 0 (none), 1 (odd), or 2 (even). Resend the communication
settings packet.
271 Flow control selection must be 0 (none), 1 (DTR), 2 (CTS/RTS), or 3 (XON/XOFF).
Resend the communication settings packet.
272 Symbol set (code page) in the System Setup packet must be 0 (Internal), 1 (ANSI), 2
(DOS 437), 3 (DOS 850), 4 (1250- Latin 2), 5 (1251- Cyrillic), 6 (1252- Latin 1), 7 (1253-
Greek), 8 (1254- Turkish), 9 (1255- Hebrew), 10 (1256- Arabic), 11 (1257- Baltic), 12
(1258- Vietnamese), 13 (852- Latin 2), 14 (855- Russian), 15 (857- IBM Turkish), 16
(860- DOS Portuguese), 17 (Wingdings), 18 (Macintosh), 19 (Unicode), 20 (BIG5), 21
(GB), 22 (SJIS to SJIS), 23 (GB to GB), 24 (BIG5 to BIG5), 25 (KSC to KSC) or
26 (UTF-8).
273 Cut adjustment must be -300 to 300 dots.
282 RS232 Trailer string is too long. Use a maximum of 3 characters.
283 ENQ Trailer string is too long. Use a maximum of 3 characters.
284 The buffer type must be D (Downloadable Fonts), F (Format), I (Image), R (Receive), T
(Transmit), or V (Scalable Fonts).
285 The storage device type in the memory configuration packet must be F (flash) or R
(volatile RAM).
286 The buffer size is invalid.
287 The printhead width must be 0.
288 The battery voltage must be 0 (15-volt battery) or 1 (12-volt battery).
289 The printer address specified in the communications settings packet must use exactly six
characters.
290 Action must be 0 (disable) or 1 (enable) for backfeed or the printer is active.
291 Dispense position must be 50 to 200 dots or the printer is active.
292 Backfeed distance must be 20 to 200 dots or the printer is active. The backfeed distance
can not be greater than the dispense position.
293 The skip index selection defined in the field must be 0 (disabled) or 1 (enabled). Correct
the packet and resend to the printer.
294 The verifier mode must be 0 (disable) or 1 (enable).
295 The verifier’s cable detect mode must be 0 (no detect), 1 (I/O cable detect), or 2 (I/O and
data cable detect).
296 Protocol must be 0. See “Defining the RFID Setup Packet” for more information.
297 Write attempts must be 3. See “Defining the RFID Setup Packet” for more information.
298 Read power must be 10. See “Defining the RFID Setup Packet” for more information.
299 Write power must be -7 to 27. See “Defining the RFID Setup Packet” for more
information.
300 Signal adjust must be 2. See “Defining the RFID Setup Packet” for more information.