8-12 Packet Reference Manual
Error Description
Code
734 The RFID tag is not programmed before the end of the label is reached. The program
cycle fails. Resend the batch to the printer.
735 RFID module hardware error. The RFID module may need to be replaced or has become
disconnected. Call Technical Support.
736 Invalid RFID command sent to the RFID module. The tag command is invalid.
737 Invalid RFID reader command sent to the RFID module. The reader setup command is
invalid.
738 Insufficient RFID power to read the TID field or program the RFID tag. There is a reader
or tag power level problem.
739 Missing specific tag. The printer cannot find the RFID tag identified by singulation.
Check supply loading or the RFID tag may be lost or defective.
740 Command, hardware, inventory, or memory allocation error. There may be an RFID
hardware or memory allocation error.
741 RFID tag missing. Tag not found in RF Field. The RFID tag was not found in the RF
Field (area inside the printer where RFID tag is programmed.) Check supply loading. If
you changed the supply or print position, make sure the RFID tag was not moved out of
the programmable range. Re-check values from the Monarch® RFID Printer Setup Utility
(http://www.servisource1.com/prnutil/rfidsetup/
).
742 Tag erase failed. The RFID tag was found in the RF Field, but could not be erased. If
this error occurs consecutively, increase or decrease the write power setting by one. If
the write power is set too high, you may affect the data programmed in adjacent labels.
743 Program tag failed. The RFID tag was found in the RF Field, but could not be
programmed. If this error occurs consecutively, increase or decrease the write power
setting by one. If the write power is set too high, you may affect the data programmed in
adjacent labels. Re-check values from the Monarch® RFID Printer Setup Utility
(http://www.servisource1.com/prnutil/rfidsetup/
).
744 Tag locked fail. The RFID tag is unable to be programmed, because it is already locked.
This is considered a bad RFID tag.
746 Lock tag fail. The RFID tag has not been locked to prevent reprogramming. This is
considered a bad RFID tag.
747 Time out failure. Any RFID command (read, program, etc.) has failed to complete in the
maximum amount of allowed time.
748 Invalid data length/data mismatch from RFID interrogator module. The RFID interrogator
module found a problem with the data received from the printer.
749 RFID verify fail. The RFID verification process failed after writing (programming) the tag.
This is considered a bad RFID tag.