2-4 Packet Reference Manual
Syntax for single packet
{ Start of Header
I, Configuration Header
A, parameter 1...parameter 5 | System Setup
}
End of Header
You can also add a configuration to RAM or specify units for supply, print, margin, and cut
positions. If you use the optional parameters with the I packet, any online configuration packets
following the split vertical bar (|) must specify distances using the selected units. However, the
test labels display the units in dots, even if you entered them in English or Metrics units.
Syntax {header,ID#,action,device | }
1. header Constant I.
2. ID# ID. Use 0.
3. action Action. Options:
A Add configuration.
U Upload User Configuration.
4. device Storage Device. Use R (Volatile RAM).
5. units Units. (Optional parameter.) Options:
E English
M Metric
G Dots
Example {I,0,A,R,E |
C,0,25,0,0,0 | }
Adds a configuration to volatile RAM and specifies English units. It also uses the default contrast,
moves print 0.25 inches closer to the bottom of the supply and does not change the margin
adjustment, prints at the default print speed, and uses the default printhead width.
If you do not use the optional parameters, the syntax for the online configuration packets does
not change. For example,
{I,C,0,50,0,0,0 | }
uses the default contrast, moves print 50 dots (0.25) inches closer to the bottom of the supply
and does not change the margin adjustment, prints at the default print speed, and uses the
default printhead width.