EasyManuals Logo

Monarch NICE 5000 User Manual

Monarch NICE 5000
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
6 Function Code Table NICE5000 User Manual
- 124 -
Function
Code
Parameter Name Setting Range Default
Unit
Property
Group Fr: Leveling adjustment parameters
Fr-00
Leveling
adjustment
function
0: Disabled
1: Enabled
0
-
Fr-01 to
Fr-28
Leveling
adjustment record
1 to 28
00000–60060
30030
mm
Group FU: Monitoring parameters
FU-03
Pre-torque current 0.0–200.0
0.0
%
FU-04
Logic information 0–65535
0
-
FU-05
Curve information 0–65535
0
-
FU-06
Speed reference 0.000–8.000
0
m/s
FU-07
Feedback speed 0.000–8.000
0
m/s
FU-08
Bus voltage 0–999.9
0
V
FU-09
Output voltage 0–999.9
0
V
FU-10
Output current 0–655.00
0
A
FU-11
Output frequency 0.00–99.99
0
Hz
FU-12
Torque current 0.0–200.0
0
%
FU-13
Output torque 0–655.00
0
A
FU-14
Output power 0.00–99.99
0
kW
FU-15
Present position 0.00–300.00
0
m
FU-16
Communication
interference
0–65535
0
-
FU-17
Encoder
interference
0–65535
0
-
FU-18
Input state 1 0–65535
0
-
FU-19
Input state 2 0–65535
0
-
FU-20
Input state 3 0–65535
0
-
FU-22
Input state 5 0–65535
0
-
FU-23
Output state 1 0–65535
0
-
FU-24
Output state 2 0–65535
0
-
FU-25
Output state 3 0–65535
0
-
FU-26
Car input state 0–65535
0
-
FU-27
Car output state 0–65535
0
-
FU-28
Hall sate 0–65535
0
-
FU-29
System state 1 0–65535
0
-
FU-30
System state 2 0–65535
0
-
FU-31
Current car load 0–255
0
-