NICE5000 User Manual 7 Description of Function Codes
- 165 -
Function Code Parameter Name Setting Range Default Unit Property
F7-01
Up call oor registered 0 to F6-00
0 - ☆
F7-02
Down call oor registered 0 to F6-00
0 - ☆
These parameters are used to set the destination floors at elevator commissioning or
repairing. They can be respectively used as the car call button, hall call up button and hall
call down button. They remain valid after the commissioning command is input, and become
invalid until they are set to 0 or the system suffers power failure.
Function Code Parameter Name Setting Range Default Unit Property
F7-03
Random running times 0–60000
0 - ☆
It is used to set the random running times of the system.
The NICE5000 has the random automatic running function. If the setting of F7-03 is greater
than 60000, the system keeps implementing random automatic running until you set F7-03
to 0.
You can set the time interval between two times of random running in F7-08.
Function Code Parameter Name Setting Range Default Unit Property
F7-04
Hall call enabled
0: Yes
1: No
0 - ☆
It is used to enable the hall call function.
0: Yes (hall call allowed)
1: No (hall call forbidden)
Function Code Parameter Name Setting Range Default Unit Property
F7-05
Door open enabled
0: Yes
1: No
0 - ☆
It is used to enable the door open function.
0: Yes (door open allowed)
1: No (door open forbidden)
Continuous running of the elevator without door open accelerates overheating of the controller
module. Long-time use in such mode may cause overheat protection, and therefore, use the
function with caution.
Function Code Parameter Name Setting Range Default Unit Property
F7-06
Overload function
0: Disabled
1: Enabled
0 - ☆