NICE5000 User Manual 7 Description of Function Codes
- 189 -
Table 7-2 LED display of the elevator state
5 4 3 2 1
Elevator state Car state Door 2 State Door 1 State
00
Inspection state
8
Elevator lock
0
Waiting
0
Waiting state
0
Waiting state
01
Shaft auto-
tuning
09
Idle elevator
parking
1
To stop
1
Door open
state
1
Door open
state
02
Micro-leveling
10
Re-leveling
at inspection
speed
2
Running
2
Door open
limit
2
Door open
limit
03
Returning to
base oor at re
emergency
11
Emergency
evacuation
operation
3
Door close
state
3
Door close
state
04
Fireghter
operation
12
Motor auto-
tuning
4
Door close
limit
4
Door close
limit
05
Fault state
13
Keypad
control
06
Attendant
operation
14
Base oor
verication
07
Automatic
running
Function Code Parameter Name Setting Range Default Unit Property
FU-05 Curve information 0–65535 0 - ●
It displays the system running curve information. LEDs 5, 4 and 3 have no display, while
LEDs 2 and 1 show the running curve information.
5 4 3 2 1
No Display Curve Information
-
00
Standby state
08
Stable-speed running segment
01
Zero-speed start segment
09
Deceleration start segment
02
Zero-speed holding segment
10
Linear deceleration segment
03
Reserved
11
Deceleration end segment
04
Startup speed stage
12
Zero speed at stop
05
Acceleration start segment
13
Current stop stage
06
Linear acceleration segment
14
Reserved
07
Acceleration end segment
15
Stop data processing
Function Code Parameter Name Setting Range Default Unit Property
FU-06
Speed reference 0.000–8.000
0 m/s ●