7 Description of Function Codes NICE5000 User Manual
- 198 -
Function
Code
Parameter Name Setting Range Default Unit Property
E0-16
Communication interference
upon 1st fault
0–65535
0 -
E0-17
Encoder interference upon 1st
fault
0–65535
0 -
E0-18
Input state 1 upon 1st fault 0–65535
0 -
E0-19
Input state 2 upon 1st fault 0–65535
0 -
E0-20
Input state 3 upon 1st fault 0–65535
0 -
E0-21
Input state 4 upon 1st fault 0–65535
0 -
E0-22
Input state 5 upon 1st fault 0–65535
0 -
E0-23
Output state 1 upon 1st fault 0–65535
0 -
E0-24
Output state 2 upon 1st fault 0–65535
0 -
E0-25
Output state 3 upon 1st fault 0–65535
0 -
E0-26
Car input state upon 1st fault 0–65535
0 -
E0-27
Car output state upon 1st fault 0–65535
0 -
E0-28
Hall sate upon 1st fault 0–65535
0 -
E0-29
System state 1 upon 1st fault 0–65535
0 -
E0-30
System state 2 upon 1st fault 0–65535
0 -
E0-31
Car load upon 1st fault 0–255
0 -
Group E1 to E9: details of the later 9 faults
Group E0 to E9 display the details of the last 10 faults.
The parameters are dened in the same way as group FU parameters.
Each time a new fault occurs, the details of this fault are recorded in group E0, and the
previous fault is recorded in group E1. When group E is full, more faults are recorded in
group FC.
When a fault is designated in FC-00, E9 is used to record details of this designated fault and
not counted here.