EasyManua.ls Logo

Monarch NICE 5000 - Page 6

Monarch NICE 5000
233 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NICE5000 User Manual Introduction
- 5 -
Repeat door close
If the door lock is not applied after the elevator performs door close for a
certain time, the elevator automatically opens the door and then closes
the door again.
Independent
command
When the main and auxiliary operation boxes are congured, they can
independently control door open/close according to the commands in
automatic running state.
Voice announcement
The elevator automatically announces information such as the running
direction and next arriving oor during running.
Leveling accuracy
adjustment
The leveling accuracy can be adjusted by setting parameters.
Auto-leveling
The systems implements automatic accurate leveling based on the oor
pulse counting and up/down leveling feedback signals.
Response at
acceleration
The system allows the elevator to automatically respond to calls from the
service oors during acceleration.
Idle elevator
returning to base
oor
In automatic running state, the elevator automatically returns to the set
parking oor and waits for passengers if there is no car call or hall call
within the set time.
Landing at another
oor
If the door open time exceeds the door open protection time but the door
open limit signal is still inactive, the elevator closes the door and then
automatically runs to the next landing oor. The system reports fault E55.
Cancellation of
wrong calls
Passengers can press the button consecutively twice to cancel wrong
calls.
Service oor setting
You can enable or disable the system service for certain oors exibly
based on actual requirements.
Time-based oor
service
You can exibly set the time periods and corresponding service oors or
select the service oors by using the service oor switchover switch.
Independent running
The elevator does not respond to any call, and the door needs to
be closed manually. In the case of group control, the elevator runs
independently out of the group control system.
Attendant running
In attendant state, the running of the elevator is controlled by the
attendant.
Low-speed self-
rescue
When the elevator is in non-inspection state and stops at non-leveling
area, the elevator automatically runs to the leveling area at low speed if
the safety requirements are met, and then opens the door.
Periodic self-check
in standby state
The systems perform self-check on the elevator periodically and records
error information within the set time, ensuring reliability and security of
elevator running.
Waiting oor
indicator
When the elevator arrives at a oor, the hall indicator of this oor
becomes ON, indicating that the elevator has arrived.
Car arrival gong
After the elevator arrives at the destination oor, the CTB gives a prompt
tone.
Hall arrival forecast
indicator
When the elevator will arrive at the destination oor soon, the MCTC-
HCB-B outputs a signal to turn on hall arrival forecast indicator.
Hall arrival gong
After the elevator will arrive at the destination oor soon, the MCTC-
HCB-B outputs a signal to turn on the hall arrival gong.

Table of Contents