1. Digital Output When active, Output is internally connected with the Ground pin. Circuit is open
when inactive. Maximum load is 25 VDC, 120 mA.
2. Ground
3. Digital Input To activate, connect the Input to the Ground pin. To deactivate, leave disconnected
or apply between 3-15 V.
4. Audio Input (line level)
5. Audio Ground
6. Audio Output (line level)
An external power amplifier should be used when connecting speakers and microphones, as shown
in the diagram.
l * Relay
l ** Switch
l M Microphone
l S Speaker