Selecting this level of security significantly impairs the decoding ability of the scanner. If this level of
security is needed, try to improve the quality of the bar codes.
• Code39
- Length1 - Use to set decode lengths (default - 0). See Decode Lengths on page 67 for more information.
- Length2 - Use to set decode lengths 4 (default - 55). See Decode Lengths on page 67 for more information.
- Verify Check Digit - Enable this feature to check the integrity of all Code 39 symbols to verify that the data
complies with a specified check digit algorithm. The digital scanner decodes only those Code 39 symbols that
include a modulo 43 check digit. Enable this feature only if the Code 39 symbols contain a modulo 43 check
digit (default - disabled).
- Report Check Digit - Transmit Code 39 data with or without the check digit. A check in the checkbox
indicates to send Code 39 data with check digit (default - disabled).
- Full ASCII - Code 39 Full ASCII is a variant of Code 39 that pairs characters to encode the full ASCII
character set. To enable or disable Code 39 Full ASCII (default - disabled),
- Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
- Convert Code39 To Code32 - Code 32 is a variant of Code 39 used by the Italian pharmaceutical industry.
Scan the appropriate bar code below to enable or disable converting Code 39 to Code 32 (default - disabled).
- Report Code32 Prefix - Scan the appropriate bar code to enable or disable adding the prefix character “A” to
all Code 32 bar codes (default - disabled).
- Security Level - Options: Security level 0, Security Level 1, Security Level 2 and Security Level 3 (default
- Security level 1).
• Interleaved 2 of 5
- Length1 - Use to set decode lengths (default - 14). See Decode Lengths on page 67 for more information.
- Length2 - Use to set decode lengths (default - 10). See Decode Lengths on page 67 for more information.
- Redundancy - Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - enabled).
- Check Digit
+ No Check Digit - A check digit is not used. (default)
+ USS Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Uniform Symbology Specification (USS) check digit algorithm.
+ OPCC Check Digit - Select to check the integrity of all Interleaved 2 of 5 symbols to verify the data
complies with either the Optical Product Code Council (OPCC) check digit algorithm.
- Report Check Digit - Transmit Interleaved 2 of 5 data with or without the check digit. A check in the
checkbox indicates to send Interleaved 2 of 5 data with check digit (default - disabled).
- Convert ITF-14 To EAN13 - Convert 14-character Interleaved 2 of 5 bar codes to EAN-13, and transmit as
EAN-13. The Interleaved 2 of 5 bar code must be enabled and must have a leading zero and a valid EAN-13
check digit. A check in the checkbox indicates that the option is enabled (default - disabled).
- I2of5 Security Level - Options: I2of5 Security level 0, I2of5 Security Level 1, I2of5 Security Level 2 and
I2of5 Security Level 3 (default - I2of5 Security level 1).
• Composite AB
- UCC Link Mode
+ Link Flag ignored - 1D component is transmitted regardless of whether a 2D component is detected.
+ Always Linked - 1D and the 2D components are transmitted. If 2D is not present, the 1D component is not
transmitted.
+ Auto Discriminate - the digital scanner determines if there is a 2D portion, then transmits the 1D
component, as well as the 2D portion if present. (default).
• UK Postal
- Report Check Digit - Transmit UK Postal data with or without the check digit. A check in the checkbox
indicates to send UK Postal data with check digit (default - disabled).
• Codabar
DataWedge Configuration | 65
MN000887A01-B | April 2015