5.1 - 6 Test Setup & Testing for 380–430 MHz
b. Enter the parameters outlined below:
Broadcast: Not supported
Broadcast Interval: 5s
Neighbour Cell Channel: 3500
Neighbour Cell Location Area: 1
Neighbour Cell Identifier: 1
Slow Re-select Threshold Above Fast: 10dB
Fast Re-select Threshold: 10dB
Slow Re-select Hysteresis: 10dB
Fast Re-select Hysteresis: 10dB
9. Configure the parameters for the “Base Service”.
a. Press the “Config” soft key twice, then go to “Configure”, followed by “Base Serv-
ice”, and press the “Select” soft key.
b. Use the default parameters outlined below:
POWER ON REGISTRATION: REQUIRED
POWER OFF DE-REGISTRATION: REQUIRED
PRIORITY CELL: YES
MINIMUM MODE SERVICE: NEVER USED
MIGRATION: SUPPORTED
SYSTEM WIDE SERVICE: NORMAL MODE
TETRA VOICE SERVICE: SUPPORTED
CIRCUIT MODE DATA SERVICE: NOT SUPPORTED
(RESERVED): NOT AVAILABLE
TETRA PACKET DATA SERVICE: NOT AVAILABLE
AIR INTERFACE ENCRYPTION: NOT AVAILABLE
ADVANCED LINK: NOT SUPPORTED
10. You have now completed all the important configurations using the configuration
menu.
Note: Please store these setting in the IFR to be recalled for future use.
Configuration of the IFR 2968 System Setup
The setup depends on the firmware version of the IFR 2968, the firmware version of the
terminal and the customer programming of the terminal.
Perform the following steps to configure the IFR 2968 System Setup with the terminal
settings:
1. Turn ON the IFR.
2. Press the “Systems” Mode Key (wait until the digital system is initialised).
3. Press the “Tetra Mobile” soft key.
4. Press the “Setup” soft key and enter the System Parameters Screen.
5. Press the “Channel Plan” or “System Type” soft key.
6. Press the “TETRA 380+0MS” soft key for 380
–430 MHz.