Symbol LS4278 Product Reference Guide4-16
Reconnect Attempt Interval (continued)
Out of Range Indicator
An out of range indicator can be set by scanning Enable Beep on Reconnect Attempt on page 4-14 and extending the time using the
Reconnect Attempt Interval beginning on page 4-15.
For example, with Beep on Reconnect Attempt disabled while the scanner loses radio connection when it is taken out of range, the
scanner attempts to reconnect silently during the time interval set by scanning a Reconnect Attempt Interval.
When Beep on Reconnect Attempt is enabled, the scanner emits 5 high beeps every 5 seconds while the reconnection attempt is in
progress. If the Reconnect Attempt Interval is adjusted to a longer period of time, such as 30 minutes, the scanner emits 5 high beeps
every 5 seconds for 30 minutes providing an out of range indicator.
Attempt to Reconnect for 30 Minutes
Attempt to Reconnect for 1 Hour
Attempt to Reconnect Indefinitely