Rate Limiting: Port Disable
Setting
Description
Factory Default
Port disable duration
(1-65535 seconds
When the ingress packets exceed the ingress rate limit, the
port will be disabled f or a certain period.
30 seconds
Ingress (frame per
second)
Select the ingress rate (f ps) limit f or all packets f rom the
f ollowing options: Not Limited, 4464, 7441, 14881, 22322,
37203, 52084, 74405
Unlimited
NOTE
The Port Disable f unction of Rate Limiting is f or multicast packets and broadcast packets.
Type 4
For Type 4, the Control Mode setting on the Rate Limiting page can be set to Normal or Port Disable.
Control Mode
Setting
Description
Factory Default
Normal
Set the max. ingress rate limit for different packet types
30 seconds
Port Disable
When the ingress multicast and broadcast packets exceed the
ingress rate limit, the port will be disabled f or a certain period.
During this period, all packets f rom this port will be discarded.
Unlimited

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies IKS-G6524A and is the answer not in the manual?

Moxa Technologies IKS-G6524A Specifications

General IconGeneral
BrandMoxa Technologies
ModelIKS-G6524A
CategorySwitch
LanguageEnglish

Related product manuals