13 MPSYSTEMS-M-001/06
5.3. Moving with a Fork Truck
To move the machine with a fork truck, the two blades must be
inserted under the long side of the machine. The base is
designed for transportation by fork truck. Insert blades
symmetrically with respect to the center of gravity of the
machine, and push them in through the whole depth of the
machine. Lifting can then be carried out. Carry out the moving
operation at a very slow speed.
Ensure the tank is completely empty of coolant when moving.
5.4. Storage
The R Series must be stored in a cool and dry environment,
avoiding all extreme conditions. Avoid freezing conditions. All
coolant must be drained from machine before being stored. If
utilizing water based coolants, the system must be flushed
before storage, please refer to coolant manufacture for correct
flushing agent. Removing all coolant from the system will
ensure coolant does not become contaminated while in the
system. Contaminated coolant may lead to malfunctions.
Not properly draining/flushing R Series before storage can lead to jammed solenoids,
diaphragms that become stuck and bacterial growth. Bacterial growth will contaminate
any coolant it comes in contact with. Contaminated coolants effectiveness is also greatly
reduced.