11 MPSYSTEMS-M-001/06
4.3. Options & Accessories
ABRV. NAME DESCRIPTION
AC Auto Cross
System automatically switches between the two filter vessels present
in unit. Once a filter bag becomes depleted, the AC system senses the
lack of flow and will switch to the clean filter. PLC will display depleted
filter #.
DP Dual Pressure
Allows for 2 set pressures that can be controlled using M-Codes.
Primary pressure 1000psi, Secondary pressure 500psi.
DSP
Dual
Simultaneous
Pressure
Each port has set pressure. Port 1 & Port 2 can run at set pressure
simultaneously.
Port 1 1000psi - Port 2 500psi
MC
MP1200
Mist Collector
Can be mounted on top of R Series or mount directly to machine tool.
Removes mist from machine tool cabinet.
HX Heat Exchanger
Removes heat from oil using ambient air temperature.
RC
Mountable
Chiller
Cools fluid using refrigerant, allows for greater fluid temperature
control.