32 MPSYSTEMS-M-001/06
7.4.1.1. R/R2 Series PLC Settings
3434 [
]
SKIM ON/OFF – Activate/Deactivate skim function. 1=ON 0=OFF
LATCH ON/OFF – Latching or Pulsing alarm signal. 1=ON 0=OFF
RD P PULSE/LATCH – Operate Reduced Pressure (RD) option
with Pulsing/Latching M-Codes. 0=Pulsing 1=Latching.
6478 [
] MIST COLLECTOR SETTINGS
MC HS RUN – Mist collector will run at high speed for set amount
of time after high pressure has stopped. Assists in clearing mist
from machine tool cabinet. Set in 1 second increments.
MC PULSE/LATCH – Ability to use Mist Collector option with
Pulsing/Latching M-Codes. 0=PULSE 1=LATCH
MC ON WITH HP – Run Mist Collector option when high pressure
is being used. 1=ON 0=OFF
MON-FRI STR/STP – Set start and stop times Moday – Friday.
24hr format.
SAT-SUN STR/STP - Set start and stop times Saturday – Sunday.
24hr format.