EasyManua.ls Logo

MP Systems R Series - R;R2 Series PLC Advanced Settings

MP Systems R Series
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32 MPSYSTEMS-M-001/06
7.4.1.1. R/R2 Series PLC Settings
3434 [
]
SKIM ON/OFFActivate/Deactivate skim function. 1=ON 0=OFF
LATCH ON/OFF Latching or Pulsing alarm signal. 1=ON 0=OFF
RD P PULSE/LATCHOperate Reduced Pressure (RD) option
with Pulsing/Latching M-Codes. 0=Pulsing 1=Latching.
6478 [
] MIST COLLECTOR SETTINGS
MC HS RUNMist collector will run at high speed for set amount
of time after high pressure has stopped. Assists in clearing mist
from machine tool cabinet. Set in 1 second increments.
MC PULSE/LATCHAbility to use Mist Collector option with
Pulsing/Latching M-Codes. 0=PULSE 1=LATCH
MC ON WITH HPRun Mist Collector option when high pressure
is being used. 1=ON 0=OFF
MON-FRI STR/STP Set start and stop times Moday Friday.
24hr format.
SAT-SUN STR/STP - Set start and stop times Saturday Sunday.
24hr format.

Table of Contents

Related product manuals