7.4.4.1. RA11 Series PLC Settings
3434 [
]
SKIM ON/OFF – Activate/Deactivate skim function. 1=ON 0=OFF
LATCH ON/OFF – Latching or Pulsing alarm signal. 1=ON 0=OFF
RDP PUL/LAT – Operate Reduced Pressure (RD) option with
Pulsing/Latching M-Codes. 0=Pulsing 1=Latching.
MM FLOW SETTING – Option to choose which high pressure
pump(s) to run. 1=ON 0=OFF
FLOW SETTING – Function allows 3gpm, 8gpm, 11gpm to
run independently. M will display on main screen in bottom
right corner when active.
o 1 = 3 GPM only
o 2 = 8 GPM only
o
3 = 11 GPM only
CALIBRATION – Calibrates flow sensor to coolant being used in
system. Will run high pressure through dump valve, back to R
Series tank for 10-15 seconds.
6478 [
] MIST COLLECTOR SETTINGS
MC HS RUN – Mist collector will run at high speed for set amount
of time after high pressure has stopped. Assists in clearing mist
from machine tool cabinet. Set in 1 second increments.
MC PULSE/LATCH – Ability to use Mist Collector option with
Pulsing/Latching M-Codes. 0=PULSE 1=LATCH
MC ON WITH HP – Run Mist Collector option when high pressure
is being used. 1=ON 0=OFF
MON-FRI STR/STP – Set start and stop times Moday – Friday.
24hr format.
SAT-SUN STR/STP - Set start and stop times Saturday – Sunday.
24hr format.