EasyManua.ls Logo

MP Systems R Series - RA11 Series PLC Advanced Settings

MP Systems R Series
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
42 MPSYSTEMS-M-001/06
7.4.4.1. RA11 Series PLC Settings
3434 [
]
SKIM ON/OFFActivate/Deactivate skim function. 1=ON 0=OFF
LATCH ON/OFF Latching or Pulsing alarm signal. 1=ON 0=OFF
RDP PUL/LATOperate Reduced Pressure (RD) option with
Pulsing/Latching M-Codes. 0=Pulsing 1=Latching.
MM FLOW SETTINGOption to choose which high pressure
pump(s) to run. 1=ON 0=OFF
FLOW SETTING Function allows 3gpm, 8gpm, 11gpm to
run independently. M will display on main screen in bottom
right corner when active.
o 1 = 3 GPM only
o 2 = 8 GPM only
o
3 = 11 GPM only
CALIBRATIONCalibrates flow sensor to coolant being used in
system. Will run high pressure through dump valve, back to R
Series tank for 10-15 seconds.
6478 [
] MIST COLLECTOR SETTINGS
MC HS RUNMist collector will run at high speed for set amount
of time after high pressure has stopped. Assists in clearing mist
from machine tool cabinet. Set in 1 second increments.
MC PULSE/LATCHAbility to use Mist Collector option with
Pulsing/Latching M-Codes. 0=PULSE 1=LATCH
MC ON WITH HPRun Mist Collector option when high pressure
is being used. 1=ON 0=OFF
MON-FRI STR/STP Set start and stop times Moday Friday.
24hr format.
SAT-SUN STR/STP - Set start and stop times Saturday Sunday.
24hr format.

Table of Contents

Related product manuals