NTP (Network Time Protocol)
The Time section shown below defines NTP (Network Time Protocol) server settings for the network
switch.
Field
Description
time.ntp.enabled
0: Disabled
1: Enabled - device will synchronise time with an NTP server (requires
network or internet access to an NTP server).
time.ntp.server1
Hostname or IP address of NTP server. For example
time.windows.net.
Logging
System message logging settings.
Field
Description
syslog.enabled
0: Disabled
1: Enabled
syslog.server_address
The hostname or IP address of the syslog server
syslog.level
All messages from 0 to the selected number will be logged.
0: Emergency
1: Alert
2: Critical
3: Error
4: Warning
5: Notice
6: Informational
7: Debug
SNMP
Simple Network Management Protocol settings. At present, the ICA only uses this protocol to monitor for
Port Up/Port Down errors on the NS50, and is not affected by the settings below, adjust only if required for
3rd party monitoring software.
Field
Description
snmp.enabled
0: Disabled
1: Enabled