Temposonics
®
R-Series SSI
Operation Manual
Temposonics
®
R-Series SSI
Operation Manual
MTS Sensors service tool
Temposonics
®
position sensors can be adapted to modified
measurement tasks very easily from outside via the connecting leads
– without opening the sensor. For this, the following MTS Sensors
programming tool is available (see page 41).
Programming kit, part no. 253 135-1 (EU) / 253 310-1 (US)
The PC programmer is a hardware converter between sensor and serial
PC interface. It can be used for adjusting sensor parameters via com-
puter and the MTS Sensors programming software. The software for
reading and adjusting the sensors requires a Windows computer with a
free USB port. You can adjust the following parameters:
Data length and data format (optionally with parity- and error bit)
Resolution and measuring direction
Synchronous / asynchronous measurement
Offset, begin of the measurement range
Alarm value (magnet was removed, magnet is missing)
Measurement filter (moving average of 2, 4 or 8 measurements for
noise reduction)
Velocity measurement or position measurement or differentiation
measurement
Step 1: Connect PC programmer
Step 2: Install software
Step 3: Start program
Fig. 56: Connect PC programmer
(for sensors with cable outlet on the left, for sensors with connector outlet on the right)
Connect the PC programmer with the sensor via the corresponding
adapter cable.
Connect the PC programmer to an USB port of the computer.
Connect the power supply via connector.
The outer contact of the connector is 0 V (ground), the inner contact
is 24 VDC.
Step 1: Connect PC programmer
Step 2: Install software
Step 3: Start program
NOTICE
Never connect / disconnect the sensor when voltage is applied.
Download current software version from www.mtssensors.com.
Copy the program SSIConfigurator.exe to your computer and start it
by double-clicking on it. The program now displays a list of available
COMs. Normally, the COM port with the lowest number (e.g. COM1)
should be selected. If a connection fails, it could be a missing driver.
In this case, download and install the USB serial converter driver from
www.mtssensors.com.
After starting the MTS SSI-Configurator, the user interface of the
connected sensor with its adjustable parameters will open (Fig. 57).
Step 1: Connect PC programmer
Step 2: Install software
Step 3: Start program
GY WHBN
WHBN
GY
PK
PK
YE
YE
GN
GN
spring terminal
USB
converter
USB
converter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MTS Systems Temposonics R Series and is the answer not in the manual?

MTS Systems Temposonics R Series Specifications

General IconGeneral
BrandMTS Systems
ModelTemposonics R Series
CategoryAccessories
LanguageEnglish

Related product manuals