SECTION 3.0 - ELECTRICAL WIRING
3.1 Field Electrical Connections at Milk Cooler's Rear Junction Box
The rear junction box is factory equipped with a quick-connect terminal strip for simple field electrical
connections. See Figure 15.
Figure 15 - Milk Cooler Electrical Terminal Strip (Rear Junction Box)
To make electrical connections to the quick-connect terminal strip:
1. Disconnect all power supplies.
2. Strip .375-inches (10 mm) of insulation off each conductor.
3. Open the quick-connect terminal connection by inserting a 3-mm screwdriver into the bottom of
socket “A”.
4. Following the electrical schematics, insert the correct conductor into terminal connection “B” and
remove the screwdriver, allowing the quick-connect terminal to close on the conductor.
Sentry II with Auto-Dosing Assembly Operating Instructions 16 Effective April 1, 2000