7.12 Milk Temperature Display
The milk temperature display provides a digital readout of the product temperature. To ensure
calibration accuracy and safe product holding temperatures, check and compare the actual product
temperature with an accurate secondary thermometer on a regular basis. See Sections 4.6 - 4.10.
7.13 Cooling Override Switch (Emergency Use Only)
1. The Sentry II has an emergency override switch located inside the enclosure. This will override the
temperature control and several other components and engage the bottom refrigeration unit(s) and
agitator(s) in an emergency situation.
2. To access and activate this switch, turn the power off to the Sentry II control box, open the door
and move this switch to the “Manual” position. Close the door, turn selector switch to the “Cool”
position, and reapply power.
IMPORTANT NOTE: There will be no automatic temperature control in the “Manual Over-Ride
Position.” When the product temperature is at a safe holding temperature, turn the power supply off to
the Sentry II control. (This is for emergency cooling only and an authorized Mueller Technician should
be contacted for immediate service.)
Sentry II with Auto-Dosing Assembly Operating Instructions 55 Effective April 1, 2000

Table of Contents

Other manuals for Mueller SENTRY II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mueller SENTRY II and is the answer not in the manual?

Mueller SENTRY II Specifications

General IconGeneral
BrandMueller
ModelSENTRY II
CategoryController
LanguageEnglish

Related product manuals