www.NabcoEntrances.com OpusControlWiringandProgrammingInstallaonManual
Rev. 3-9-18 P/N C-00139
Optional Setting
Parameter Range Default Description
DN 1309
Latch Check (LCHK)
Lockout Angle
Lockout Angle
Available Angle
Con nuous Safety
Available Angle
for Low Energy
Door Mount
Approach Side
Sensor
Available Angle Safety
with lockout
Available Angle Safety
with Lockout
SAFETY WITH LOCKOUT AREASLOCKOUT PARAMETERS
Stop Force Adjustment 0 - 7 3 Determines how the door reacts to a connuous safety signal:
Slow Open, Stop, or Slow Close
Anti-Slam Open? Yes No Choose Yes if the door slams open
No
Sim Pair Setting Single Door Single Door Select type of Door
Normal Sim Pair If selected; before returning to last screen, opon to copy
sengs to other Control is given.
Double Egress The Acvaon signal (only) is shared between doors. All other
signals are independent.
Overlap Sim Pair
►
►
1. Have acvaon signals connected to it
2. Be set to “Overlap Sim Pair”
►
►
►
DN 1558
Open fi rst,
Latch check is wide
Overlap Sim Pair
Opus Se ngs
Normal Sim Pair
Ac va on No Ac va on
Connec on