Opus Control Wiring and Programming Installaon Manual www.NabcoEntrances.com
P/N C-00139 Rev 3-9-18
SECTION 12.5: Lock
DN 1332
1413121110
98
7654321
* Fail-Secure
Electric Strike
* Fail-Secure Lock Shown,
Fail-Safe and Mag-Locks will use
N.C. instead of N.O.
Power Supply Fo
r
Electric Strike
N.O.
COM
N.C.
Varistor
(MOV, TVS)
!!! DO NOT!!!
POWER ELECTRIC STRIKES OR LOCKS FROM OPUS CONTROL
Aux. Output 3
Note: Must adjust Se ngs for Auxilliary Output #3 for Type of Electric Lock