8 of 35
Opus Control Wiring and Programming Installaon Manual www.NabcoEntrances.com
P/N C-00139 Rev 3-9-18
CHAPTER 8: LCD CATAGORY SCREENS
Passcode
Go to Se ng Menu
Stroke Learning
Yes No
UNIT SPECS
ERROR ANSI TERMINAL
Long
Push
LEVEL 1
LEVEL 2
Rotate Dial to navigate screen. Short Push Dial to select
Se ng Category
LEVEL 3
ParameterOp ons
Base Se ng Operator Type/Low or Full Energy/Handing/Encoder
Movement Se ng
(Rotate Rotary Dial)
Open Speed/Back Check Speed/Back Check Range/Close Speed/Latch Check Speed/
Latch Check Range/Open Timer/Reac on Power/Open Recycle Sens/Close Recycle Sens/
A er Open Recycle
Op onal Se ng Hold Close Force/Power Close Range/Manual Open Func on/Manual Open Sens/Manual
Open Timer/BCHK Lockout Angle/LCHK Lockout Angle/Stop Force adjustment/SimPair Se ng
Output Se ng Output1 Se ng/Output2 Se ng/RelayOutput3 Se ng/Open Delay Timer/
Sequence Delay Timer/Lock Condi on
Input Se ng Input 62 Se ng/Input 62 Open Timer/Input H Se ng/Input H Open Timer/Input 61 Circuit/
Input 62 Circuit/Input 6B Circuit/Input SWL Circuit/Input BA Circuit/6B Stop Closing/A er 6B
Open?/61 Monitoring/62 Monitoring/6B Monitoring/SWL Monitoring
History Se ng Opera on Cnt/Open Recycle Cnt/Close Recycle Cnt/Latest Recycle Posi on
DN 1334
LEVEL 4
Push and Hold Rotary Dial (2 Sec.)
Rotate
Dial
Rotate
Dial
Rotate
Dial
Short
Push
Figure 3
SECTION 8.1: Level One: Specicaon Screens
Type: GT710 Swing
Status: Slow Closing
Error: -----
Ac va on: IN EXT
Switch: LCHK BCHK
Other: BA 6B SLS
Keep Pushing Switch
=> Se ng Mode
DN 1241
UNIT SPECS
ANSI specs (reference)
Opening Time to 80 deg
Closing Time to LCHK
LCHK to FullClosed
8BA112VDC
9SQ2GND
10 Mul 361
11 M0 462
12 M1 56B
13 Out3 6SWL
14 GND 7 Out2
Terminal
Error Screen
Mfg: 11/2016 Rev.B:21
Rotate
Dial
Rotate
Dial
Rotate
Dial
ANSI SPECS
ERROR SPECS
TERMINAL SPECS
Figure 4
Level One screens are used to inform the User all specicaons that have already been programmed into the Opus Control. If a
specicaon needs to be changed, the User must reprogram the Opus Control within the Level Three screen, or Level Four screen.
When Power is turned ON for the rst me, the Door does not move. Instead, an LCD screen will illuminate to display a Level One:
Unit Specicaon screen (Default screen). There are (4) Level One screens:
X