GEM-P1632 Programming Instructions
NAPCO Security Systems
WI897B 8/98
Page 16
Key Fob Transmitters
(Press the
(
)
button to set cursor.)
Keyfobs can be programmed as “Arm/Disarm devices using their buttons
(refer to WI752). For each Key Fob Transmitter, enter:
the Key Fob Transmitter number (01–08).
area number to which transmitter is assigned (1 or 2); enter 0 to disable
keyfob.
the 6-digit RF ID # printed on the transmitter (enter all numbers and/or
letters, including leading “0”s, if any).
1-digit checksum number printed on the transmitter (enter all numbers
and/or letters, including leading “0”s, if any).
Aux-1 Option (see key fob
aux 1 & aux 2 options).
Aux-2 Option (see key fob
aux 1 & aux 2 options).
Note:
If the Key Fob is con-
verted for Two Button
“Emergency Use” (by cutting
an internal jumper), both top or
bottom buttons must be depressed to activate an alarms. In this case, the
Aux-1 and Aux-2 cannot be programmed.
Press
to save. Press NEXT (
) button to proceed.
Key Fob Zone Assignment
(refer to display as shown on the previous pa
g
e: press the
(
)
button to
g
o backwards.)
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point
3; A2 = point 4. Up to 32 key fobs (using 1 button) or 16 key fobs (using 2 buttons) or 8 key fobs (using all 4 buttons) or any
combination up to a maximum of 32 controlled zones can be assigned, providing multiple wireless panic buttons on a
system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone number with
description/location.
To assi
g
n a key fob to a zone:
program the keyfob as you would a transmitter, entering the keyfob's
ID code, check sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone may be
hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output).
NOTE:
If assigning
a key fob to a zone, the “ON/OFF” buttons on the key fob will no longer arm/disarm the system. The key fob is converted
to a “panic only” device.
Dealer Code
Directly enter the Dealer Code (default = 456789), including leading zeros.
Use the
through
buttons. NOTE: Pres the
button for a
zero. Press
to save.
Re-enter the Dealer Code to verify the previous code. Press
to save.
Press NEXT (
) button to proceed.
CLEAR PROGRAM:
Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode,
press the
button to enter the Address Program Mode; (b) access Location 1197 (Clear Program); (c) press and
start over.
(Direct Entry)
"

(Direct Entry)
""""""
(Direct Entry)
&"""
(Direct Entry)

(Direct Entry)

ZONE DESCRIPTIONS:
GEM-RP2ASe2 cannot be used to enter
Zone Descriptions. To enter Zone Descriptions you
must use the
GEM-RP1CAe2 Keypad or the Napco Quickloader Software.
EASY MENU DRIVEN PROGRAM MODE
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
•(blank) None
1 Relay Group 1
2 Relay Group 2
3 Relay Group 3
4 Relay Group 4
5 Relay Group 5
6 Relay Group 6
DATA
ENTRY
AUX 1/AUX 2 OP-
TIONS
7 Relay Group 7
8 Relay Group 8
9 Keypad Panic
0 Aux K.P. Panic
B Instant
C Toggle Aux Relay
EXIT DEALER PROGRAM MODE:
This completes the custom default program. Press the
button to enter the
Direct Address Program Mode for further programming or press the
button once again to end all programming and
resume normal keypad operation.

Table of Contents

Other manuals for NAPCO Gemini GEM-P1632

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P1632 and is the answer not in the manual?

NAPCO Gemini GEM-P1632 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P1632
CategoryControl Panel
LanguageEnglish

Related product manuals