NAPCO Security Systems
GEM-P1632 Programming Instructions
WI897B 8/98
Page 35
AREA OPTIONS:
Each relay event can be assigned to Area 1, Area 2
or both Area 1 & Area 2.
2. Select the area from the table shown;
enter in corresponding right digit address
location (left digit is not used).
("!%
ADDRESS 0750-0754 (RELAY EVENT 1)
0750 0751 0752 0753 0754
LRLRLRLRLR
(•) (•)
ADDRESS 0755-0759 (RELAY EVENT 2)
0755 0756 0757 0758 0759
LRLRLRLRLR
(•) (•)
ADDRESS 0760-0764 (RELAY EVENT 3)
0760 0761 0762 0763 0764
LRLRLRLRLR
(•) (•)
ADDRESS 0765-0769 (RELAY EVENT 4)
0765 0766 0767 0768 0769
LRLRLRLRLR
(•) (•)
ADDRESS 0770-0774 (RELAY EVENT 5)
0770 0771 0772 0773 0774
LRLRLRLRLR
(•) (•)
ADDRESS 0775-0779 (RELAY EVENT 6)
0775 0776 0777 0778 0779
LRLRLRLRLR
(•) (•)
ADDRESS 0780-0784 (RELAY EVENT 7)
0780 0781 0782 0783 0784
LRLRLRLRLR
(•) (•)
ADDRESS 0785-0789 (RELAY EVENT 8)
0785 0786 0787 0788 0789
LRLRLRLRLR
(•) (•)
ADDRESS 0790-0794 (RELAY EVENT 9)
0790 0791 0792 0793 0794
LRLRLRLRLR
(•) (•)
ADDRESS 0795-0799 (RELAY EVENT 10)
0795 0796 0797 0798 0799
LRLRLRLRLR
(•) (•)
ADDRESS 0800-0804 (RELAY EVENT 11)
0800 0801 0802 0803 0804
LRLRLRLRLR
(•) (•)
ADDRESS 0805-0809 (RELAY EVENT 12)
0805 0806 0807 0808 0809
LRLRLRLRLR
(•) (•)
ADDRESS 0810-0814 (RELAY EVENT 13)
0810 0811 0812 0813 0814
LRLRLRLRLR
(•) (•)
ADDRESS 0815-0819 (RELAY EVENT 14)
0815 0816 0817 0818 0819
LRLRLRLRLR
(•) (•)
ADDRESS 0820-0824 (RELAY EVENT 15)
0820 0821 0822 0823 0824
LRLRLRLRLR
(•) (•)
ADDRESS 0825-0829 (RELAY EVENT 16)
0825 0826 0827 0828 0829
LRLRLRLRLR
(•) (•)
RELAY EVENT OPTIONS
RELAY # AREA Timeout Event ID COND.
LRLRLRLRLR
(•) (•)
1
2
3
4
5
DATA
ENTRY
RIGHT
blank (•)
1
2
3
4
5
6
7
8
RELAY #
NONE
1
2
3
4
5
6
7
8
[Default = blank (•) blank (•) from address 0750-0829]
RELAY # OPTIONS:
Each relay event can be assigned to any of the 8
available external relays from Relay Module RM3008. Multiple relay
events can drive the same External Relay.
1. Select the relay from the table shown; enter in corresponding
right digit address location (left digit is not used).
DATA
ENTRY
RIGHT
blank (•)
1
2
3
OFF/ON AREA
DISARM
NONE
Area 1
Area 2
Area 1 & Area 2
TIMEOUTS:
Each relay event can be assigned a timeout depending on Alarm Type option.
3. If Alarm Type (see next page) is selected for timeout in minutes or seconds, select the timeout from the table shown in minutes
or seconds and enter in corresponding address location (left digit and right digits).
DATA ENTRIES
LEFT RIGHT
blank (•) blank (•)
blank (•) 1
blank (•) 2
blank (•) 3
blank (•) 4
blank (•) 5
blank (•) 6
blank (•) 7
blank (•) 8
blank (•) 9
blank (•) 0
TIMEOUT
0 min./sec.
1 min./sec.
2 min./sec.
3 min./sec.
4 min./sec.
5 min./sec.
6 min./sec.
7 min./sec.
8 min./sec.
9 min./sec.
10 min./sec.
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
DATA ENTRIES
LEFT RIGHT
blank (•) B
blank (•) C
blank (•) D
blank (•) E
blank (•) F
1 blank (•)
11
12
13
14
15
TIMEOUT
11 min./sec.
12 min./sec.
13 min./sec.
14 min./sec.
15 min./sec.
16 min./sec.
17 min./sec.
18 min./sec.
19 min./sec.
20 min./sec.
21 min./sec.
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
DATA ENTRIES
LEFT RIGHT
16
17
18
19
10
1B
1C
1D
FF
TIMEOUT
11 min./sec.
12 min./sec.
13 min./sec.
14 min./sec.
15 min./sec.
16 min./sec.
17 min./sec.
18 min./sec.
2550 min./sec.
TIMEOUTS
(Alarm Type is selected for
Timeout Type in min. or sec.)
For a desired delay/timeout not listed
do the following:
A. Choose a desired delay/timeout,
ex: 20 min.
B. Divide it by 16
1 Quotient Left Digit
16 20
16
4 Remainder Right Digit
EVENT ID CODES & CONDITIONS