NAPCO Security Systems

GEM-P1632 Programming Instructions
WI897B 8/98
Page 25
[Default = blank (•) blank (•)]
Default depends on Easy Menu Question “
   
”.
If yes, then [Default = •(blank) 1]. If no, then [Default = •(blank) •(blank)].
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
[Default = blank (•) blank (•)]
!%
ADDRESS 0718
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
LEFT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
RESERVED
Enable AutoArm if not
closed at end of windows
Disable Time/Date
at Keypad
RESERVED
RIGHT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Opening Report Only
after Alarm Report
Closing Report Only on
Conditional Close
Incl. Sel./Grp. Bypass in
Cond. Close /Status
Status
Report
ADDRESS 0719
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
LEFT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Access Control
on PGM2 Output
Maintained Keyswitch
Arming
Enable
Manager's Mode
Disable
Instant Mode
RIGHT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Auto Bell Test
on Arming
Auto Reset after Burglary
Output Timeout
Suppress Bypass
Reminder when Armed
Enable Local Alarm on
First “ZoneAND” Trip
ADDRESS 0720
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
LEFT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Disable Keypad Function
Mode Download
Disable Callback
Download
PGM2 Output Chirp on
Keyfob Arming
Change Pulse Output to
Cadence
RIGHT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Interior 1
Normally Bypassed
Enable Global
Ambush Code *
Reset Day Zone with
Arm/Disarm Only
Enable
Residential Fire
ADDRESS 0721
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
LEFT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Line-Fault Test only
when Armed
Enable
Line-Fault Test
RESERVED
RESERVED
RIGHT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Enable Zone Doubling
(Zones 9-16)
Wireless Trouble
Activates Telco 1
Wireless Trouble
Activates Telco 3
RESERVED

1. Select the desired option by circling
the data values for each digit (left and right).

2. Add the data values (ex: 15=1+2+4+8) from the selected options.

3. Enter in address location (left and right digits).
NOTE:
To select “Line-Fault Test only when Armed”, you must also select
“Enable Line-Fault Test” at address 0721.
PROGRAMMING OPTIONS & WORKSHEETS
ADDRESS 0722
LEFT DIGIT (SUM
OF DATA VALUES)
RIGHT DIGIT (SUM
OF DATA VALUES)
LEFT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Don't Clear PGM2 Output
with Arm/Disarm
2nd Ring Download
(Dis. Ans. Machine Overide)
RESERVED
RESERVED
RIGHT DATA
VALUES
(CIRCLE
)
1
2
4
8
SYSTEM OPTIONS
Automatic
Interior Bypass
Veri-phone Zones Trip
PGM2 Output
Veri-phone Zones over
Priority Alarms
Resound on Wireless
Smoke Low Battery
* NOTE:
If “Enable Global Ambush
Code” in Address 0720 is selected,
then program the 2-digit “Global Am-
bush Code” in Address 1054. If Ad-
dress 1054 is left blank (•), then, the
2-digit “Global Ambush Code” will be
“99”.

Table of Contents

Other manuals for NAPCO Gemini GEM-P1632

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P1632 and is the answer not in the manual?

NAPCO Gemini GEM-P1632 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P1632
CategoryControl Panel
LanguageEnglish

Related product manuals