GEM-P1632 Programming Instructions
NAPCO Security Systems
WI897B 8/98
Page 24
See NOTE
[Default = blank (•) blank (•) from address 0478-0485]
[Default = blank (•) blank (•) from address 0470-0477]
[Default = blank (•) blank (•) from address 0460-0469]
"!
SYSTEM RESPONSE AC-
TIVATED BY GLOBAL
EVENT/TROUBLE
Alarm Output
Pulsed Alarm Output
PGM1 Output
PGM2 Output
Report Event Telco 1
Report Restore Telco 1
Report Event Telco 3
Report Restore Telco 3
GLOBAL SYSTEM EVENT/TROUBLE
LEFT DATA VALUES (CIRCLE
)
Bell
Superv.
EZM
TAMPER
AC FAIL LOW
BATTERY
8
421
8
421
8421
8421
8421
8
4
21
8421
8
4
21
ADDRESS
0460-0469
LEFT ADDR RIGHT
0460
0461
0462
0463
0464
0465
0468
0469
GLOBAL SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
)
MEMORY
FAILURE
RF RCVR.
TROUBLE
TELCO
FAILURE
TEST
TIMER
842
1
842
1
842
1
842
1
84
2
1
84
2
1
84
2
1
84
2
1
SYSTEM RESPONSE AC-
TIVATED BY AREA 1
EVENT/TROUBLE
Pulsed Alarm Output
Alarm Output
PGM1 Output
PGM2 Output
Report Event Telco 1
Report Event Telco 3
AREA 1 SYSTEM EVENT/TROUBLE
LEFT DATA VALUES (CIRCLE
)
Keyfob
Low Batt.
FAIL TO
CLOSE
FAIL TO
OPEN
KEYPAD
TAMPER
8421
8421
8421
8421
8421
8421
ADDRESS
0470-0477
LEFT ADDR RIGHT
0470
0471
0472
0474
0475
0477
AREA 1 SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
)
KEYPAD
AUXILIARY
KEYPAD
FIRE
KEYPAD
PANIC
AMBUSH
8421
8421
8421
8421
8421
8421
SYSTEM RESPONSE AC-
TIVATED BY AREA 2
EVENT/TROUBLE
Pulsed Alarm Output
Alarm Output
PGM1 Output
PGM2 Output
Report Event Telco 1
Report Event Telco 3
AREA 2 SYSTEM EVENT/TROUBLE
LEFT DATA VALUES (CIRCLE
)
Keyfob
Low Batt.
FAIL TO
CLOSE
FAIL TO
OPEN
KEYPAD
TAMPER
8
421
8
421
8421
8421
8421
8421
ADDRESS
0478-0485
LEFT ADDR RIGHT
0478
0479
0480
0482
0483
0485
AREA 2 SYSTEM EVENT/TROUBLE
RIGHT DATA VALUES (CIRCLE
)
KEYPAD
AUXILIARY
KEYPAD
FIRE
KEYPAD
PANIC
AMBUSH
8421
8421
8421
8421
8421
8421

1. Select the desired option by circling
the data values for each digit (left and right).

2. Add the data values (ex: 15=1+2+4+8) from the selected options.

3. Enter in address location (left and right digits).
NOTE:
Dark shaded data value box shows option not available.
PROGRAMMING OPTIONS & WORKSHEETS
[Default = blank (•) blank (•)]
Global
Ambush Code
ADDRESS 1054
LEFT RIGHT
GLOBAL AMBUSH CODE:
It is the 2-digits entered immediately prior to the regular disarm code.
If “Enable Global Ambush Code” (Address 0720) is selected and Address 1054 is left blank (•), then
the 2-digit Global Ambush Code is “99”. If “Enable Global Ambush Code” is selected and Address
1054 is
not
left blank (•), then the 2-digit Global Ambush Code is the two digits entered in address
1054.

Enter in address location (both left and right digits) ; valid entries are 1-9.

Table of Contents

Other manuals for NAPCO Gemini GEM-P1632

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P1632 and is the answer not in the manual?

NAPCO Gemini GEM-P1632 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P1632
CategoryControl Panel
LanguageEnglish

Related product manuals