GLOSSARY
Watch Mode (by Area)
See Day Zone
Zone ANDing, Groups 1–2 (Not for UL installations); Enable Local Alarm on First Zone “AND” Trip (Not for UL installations)
Up to two groups of at least two zones each can be “AND”ed (Address 0534-0537, 0589-0592, 0644-0647, 0699-0702), wherein the
system will go into alarm only if any two zones of the group are tripped within a prescribed time. This feature is designed to afford
redundant protection for devices, such as glass break detectors, PIRs, etc., that may show a tendency to false under certain condi-
tions. Program each group for any number of Zones 1–32. All zones in any group must be within the same area. Do not mix 24-Hour
Zones and non-24-Hour Zones within the same group. Do not include a Panic Zone as part of any group.
Note:
Any zone that is bypassed or goes into swinger shutdown will automatically disable Zone Anding for the entire group.
If “Enable Local Alarm on First ZoneAND Trip” (Address 0719) is programmed, a trip on any zone of the group will cause an alarm
indication at the keypad only; there will be no communication to the central station.
Zone Area 1–Zone Area
2 See Areas
Zone Number on Pulse Alarm
See Data Formats: Two-Digit Format
Zone Type
See Data Formats: Modem Formats
2-Wire, 4-Wire Smoke Detectors
See Smoke Detectors
4-Wire Bus Failure
See Bus Failure
24-Hour Zone
A zone selected for “24-Hour Zone” (Address 0499, 0554, 0609, 0664) that provides protection at all times, whether or not the sys-
tem is armed. If “Alarm Output”, “Pulsed Alarm Output”, “PGM1 Output” , “PGM2 Output” and “Keypad Sounder on Alarm” are
not
selected, then the zone is programmed for silent alarm. In this case, the green LED on the keypad will go out if the zone is tripped.
Note:
Do not program a Day Zone as a 24-Hour Zone.

Table of Contents

Other manuals for NAPCO Gemini GEM-P1632

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO Gemini GEM-P1632 and is the answer not in the manual?

NAPCO Gemini GEM-P1632 Specifications

General IconGeneral
BrandNAPCO
ModelGemini GEM-P1632
CategoryControl Panel
LanguageEnglish

Related product manuals