46 All technical manuals are available in PDF format at tech.napcosecurity.com Napco iSecure Security System
Programming: Glass-Break Sensors
1. Go to www.iSecureByNapco.com and log into your iSe-
cure account.
2. Click Sensor Configuration.
3. In the SENSOR CONFIGURATION screen (shown be-
low), program the installed glass break sensors as indicat-
ed (when finished, click Save).
ISEC-GLASSBREAK
Wireless Glass-Break Sensor
SENSOR TYPE
Select "Glass
Break".
ENABLE REPORTING
Check to enable central
station reporting
1
2
3
5
6
SENSOR ID
Type in the 7
digit sensor ID
# for the device
4
DESCRIPTION
Type the sensor descrip-
tion you wish to appear
on the keypad display
AREA
Default = 1. See the key-
pad Operating Guide for
the definition of "Area".
SENSOR FUNCTION
For most installations, we recommend selecting "Instant". With "Instant", when
the system is armed, the sensor will immediately trigger an alarm when the sound
of glass breaking is detected. If you select "24Hr Zone Audible", the system will
trigger an alarm when the sound of glass breaking is detected, whether the sys-
tem is armed or disarmed.
SIGNAL STRENGTH
Relative intensity of the last transmis-
sion, on a scale of 1-10 (10 being the
strongest). Note: A reading of 3 or
less indicates reception may be erratic;
relocate the sensor closer to the Hub.