Napco iSecure Security System All technical manuals are available in PDF format at tech.napcosecurity.com 53
Programming: Sirens
1. Go to www.iSecureByNapco.com and log into your iSe-
cure account.
2. Click Wireless Modules > Siren.
3. In the SIRENS screen (shown below), program each siren
in your system (up to 4 allowed) (when finished, click
Save).
Note: The Hub's integral siren only activates upon an Area 1
alarm. All other external sirens activate upon an alarm in
any Area.
ISEC-WL-SIREN Wireless Siren
TYPE
Sirens can be powered
by an AC power supply
(plugged into a 120VAC
unswitched wall outlet) or
with batteries. Select the
power type used by your
siren.
NAME
Type the siren
description you
wish to appear
on the keypad
display
RF ID
Type in the
7 digit sen-
sor ID # for
the device
STATUS
Indicates the current con-
dition of the siren, whether
active or inactive; to re-
learn the unit, click Re-
learn.
SIGNAL STRENGTH
Relative intensity of the
last transmission, on a
scale of 1-10 (10 being
the strongest). Note: A
reading of 3 or less indi-
cates reception may be
erratic; relocate the sen-
sor closer to the Hub.
1
2
3
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NAPCO iSecure and is the answer not in the manual?

NAPCO iSecure Specifications

General IconGeneral
BrandNAPCO
ModeliSecure
CategorySecurity System
LanguageEnglish

Related product manuals