User Guide
76
www.nec-computers.com
Caution
To power on the server from the UPS (Uninterruptible Power
Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once
and then on again, depending on the setting of "AC LINK."
Thermal Sensor Disabled
Enabled
Specifies whether the thermal
sensor monitoring function is
enabled or not.
If a thermal error is detected
while this parameter is enabled,
the system stops at the end of
the POST.
BMC IRQ Disabled
IRQ 11
Determines the routing of the
BMC Interrupt.
POST Error Pause Disabled
Enabled
Specifies whether the system
waits for user intervention on
critical POST errors.
If no keyboard is connected to
the system, this option is
ignored and the system always
continues to bootup.
AC-LINK Stays Off
Last State
Power On
Sets the AC-LINK feature.
Determines the mode of
operation if a power loss
occurs.
Power On Delay
Time (Sec)
20 - 255 Sets the power-on delay time
whithin a 0 to 255 seconds
range.
This parameter is valid when
“Power On “ or “Last State” is
specified for AC Link.
Platform Event
Filtering
Disabled
Enabled
This item is meaningless when
the notification feature of the
Remote Management Card is
enabled.
System status before AC power off
Setting of AC LINK
Stay Off Last State Power On
Operating Off On On
Aborting (DC power being off also) Off Off On
Forced shutdown Off Off On
Table 15: Server Menu (Continued)
Feature Choices or
Display Only
Description Your Setting