EasyManua.ls Logo

NEC Express5800 120Rj-2 - Page 94

NEC Express5800 120Rj-2
367 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Guide
94
www.nec-computers.com
Creation of virtual disks
- RAID level Settings
- Stripe Block size Settings
- Read Policy/Write Policy/IO Policy Settings
Indication of the configuration information and status of the virtual disk
Virtual Disk removal
Configuration clearing
Initialization
Consistency Check
Manual Rebuild
Reconstruction
Notes on when creating a Virtual Disk
The HDDs configuring the disk group should have the same capacity and rotation
speed.
Be sure to execute a Consistency Check after the VD creation.
When installing an OS in VD under the Internal RAID Controller, create a VD
dedicated to the OS installation.
WebBIOS cannot be handled via the remote console functions of NEC
DianaScope.
The physical drive numbers shown in WebBIOS and those shown in the Universal
RAID Utility are identified as follows.
-WebBIOS
Enclosure number and Slot number shown in the Physical Drives box*
*"X:X:X" shown in the Physical Drives box represents the Connector
number:Enclosure number:Slot number.
- The Connector number is not supported on this server, thus, it is always
indicated as "()".
- The Enclosure Number is always "1".
- The Slot number represents a slot number of disk bay.
- Universal RAID Utility
The Enclosure number and Slot number are shown in the Physical Device
Properties

Table of Contents